Electrical & Automation Panels — CM Aquatechnik water treatment equipment
Available brands: ABB Siemens Schneider Electric Allen-Bradley (Rockwell Automation)

Electrical & Automation Panels

ABB Control Panel MCC PLC SCADA Switchgear

Electrical and automation panels: MCCs, distribution boards and PLC/SCADA control panels to IEC standards, factory acceptance tested before dispatch.

Technical Specifications

Panel TypesMCC · PDB · LCP · JB · SCADA · PLC cabinet
PLC PlatformSiemens S7-1200/1500 · Allen-Bradley (custom)
SCADA SoftwareSiemens WinCC · Ignition
Drive BrandsABB · Siemens · Schneider (VFDs)
Switchgear BrandABB · Schneider Electric
Enclosure StandardIP54 (indoor) · IP65 (outdoor)
Busbar Rating400 – 3,200 A
Short Circuit RatingUp to 65 kA (type tested)
Voltage400V 3-phase 50Hz (standard)
StandardsIEC 61439 · IEC 61010 · CE · ATEX
48h quote turnaround CE & DIN certified Worldwide shipping Technical support included

Key Features

  • Full IEC 61439-2 type-tested MCC for proven safety and standards compliance
  • Factory Acceptance Test (FAT) with customer witness before dispatch
  • Siemens TIA Portal programming with structured function block design
  • Modbus TCP, OPC-UA, and PROFINET for plant-wide SCADA integration
  • ATEX Zone 2 panel versions for gas or dusty hazardous area installations
  • As-built drawings, I/O schedules, wiring diagrams, and software code supplied

Applications

  • Water treatment plant PLC/SCADA control
  • Wastewater pump station MCC
  • MBR and RO system automation
  • Municipal WWTP full automation upgrade
  • Industrial process water control system
  • SCADA network integration

Product Overview

CM Aquatechnik designs, builds, and supplies motor control centres (MCC), main power distribution boards, instrument junction boxes, and custom PLC/SCADA control panels to IEC standards for water and wastewater treatment plants. Panels are built using ABB, Schneider Electric, or Siemens components, and are factory acceptance tested (FAT) before dispatch.

Automation scope includes Siemens S7-1200/S7-1500 PLC programming, WinCC or Ignition SCADA development, HMI touchscreen panels, variable frequency drives (VFD), and remote I/O for distributed control. Full As-Built documentation, loop test certificates, and O&M manuals are provided.

What the scope includes
  • Motor control centre — incoming feeder, busbars and one outgoing feeder per motor with protection and a direct-on-line starter, soft starter or frequency converter.
  • PLC cabinet — controller, input and output modules, power supplies, network components and an operator panel. Remote I/O stations in the plant shorten the cable runs.
  • Local panels and junction boxes — for operation at the machine and for collecting field signals.
  • SCADA — plant overview, alarms, trends, reports and secured remote access.

The work follows a fixed sequence: motor and signal lists, single-line diagram, circuit diagrams, functional description, software, factory acceptance test, installation, loop checks and commissioning, and finally the as-built documentation.

Design data we need
  • Motor list — power, voltage and type of starting for every drive.
  • Instrument and signal list — analogue and digital inputs and outputs, and bus devices.
  • Power supply — voltage, frequency, network type and the short-circuit current at the incoming point.
  • Environment — indoor or outdoor, ambient temperature, dust, humidity, and corrosive gases such as hydrogen sulphide, which call for filtered or closed-loop cooling and coated electronics.
  • Site standards — preferred makes of PLC, drives and switchgear, and the interface to an existing control system.
  • Hazardous areas — zones in which equipment must be explosion-protected.
  • Availability — redundant controllers, uninterruptible power supply and emergency operation.

More about programming and commissioning on our automation page.

What determines the cost
  • Motor feeders — their number and power, and the share of frequency converters.
  • Signals — the number of inputs and outputs and the network structure.
  • Enclosures — painted steel indoors; stainless steel or air-conditioned outdoor cabinets cost more.
  • Software — the number of control loops and sequences, SCADA screens and reports.
  • Redundancy and testing — redundant systems, witnessed tests and the documentation required.
Frequently asked questions

Which standards are your panels built to?

Panels are designed and built to IEC standards, with motor control centres type-tested to IEC 61439-2 and short-circuit ratings of up to 65 kA. Enclosures are supplied to IP54 for indoor and IP65 for outdoor installation, and ATEX Zone 2 versions are available for hazardous areas.

Which PLC and SCADA platforms do you work with?

Our standard platform is Siemens S7-1200/S7-1500, programmed in TIA Portal with a structured function block design, and Allen-Bradley is available as a custom option. SCADA systems are developed in Siemens WinCC or Ignition and connected via Modbus TCP, OPC-UA and PROFINET.

How are the panels tested and documented?

Every panel undergoes a Factory Acceptance Test (FAT) before dispatch, which customers are welcome to witness. The documentation package includes as-built drawings, I/O schedules, wiring diagrams, loop test certificates, O&M manuals and the software code.

What information do you need for a quotation?

Please provide the panel types required, a list of motors and drives with their ratings, the I/O list or P&ID, the supply voltage and prospective short-circuit current, the installation environment (indoor or outdoor, ATEX zone if applicable), preferred component brands and PLC/SCADA platform, and the documentation required. Send us your requirements and we will prepare a proposal within 48 hours.

Last updated: · Technical data are typical values; the final design follows your water analysis and project data. Stock availability in Neuss and lead times are confirmed with the quotation.